Laminar flow occurs when a fluid moves smoothly in parallel layers with minimal mixing and turbulence. In fluid mechanics, ensuring laminar flow within a pipe is essential for precise control of flow characteristics, especially in engineering applications. The key factor in determining whether flow remains laminar is the Reynolds number, a dimensionless quantity that depends on the fluid's velocity, density, viscosity, and the pipe's diameter. A Reynolds number of 2100 or lower indicates laminar flow, while higher values lead to turbulence.
For air flowing through a pipe at standard atmospheric conditions and a given mass flow rate, the velocity of the fluid must be controlled to maintain laminar conditions. Since velocity depends on the flow rate and the cross-sectional area of the pipe, the pipe diameter plays a crucial role. By substituting the velocity expression into the Reynolds number formula and solving for the diameter, it is possible to determine the minimum required pipe size.
Using standard values for air density and viscosity at 300 Kelvin, the volumetric flow rate can be computed. This, in turn, allows for the calculation of the necessary pipe diameter. To ensure a Reynolds number of 2100 or lower, the minimum allowable diameter for the pipe is found to be approximately 0.46 meters. This calculation ensures that the flow remains smooth and predictable, avoiding turbulence that could disrupt performance.
From Chapter 21:
Now Playing
Flow in Pipes
127 Views
Flow in Pipes
867 Views
Flow in Pipes
817 Views
Flow in Pipes
760 Views
Flow in Pipes
147 Views
Flow in Pipes
98 Views
Flow in Pipes
792 Views
Flow in Pipes
742 Views
Flow in Pipes
110 Views
Flow in Pipes
518 Views
Flow in Pipes
459 Views
Flow in Pipes
376 Views
Flow in Pipes
463 Views
Copyright © 2025 MyJoVE Corporation. All rights reserved